decoration handbook

RETAIL DESIGN AND DELIVERY

Shop Front Design

Your mission

Glazing

Product or service

Entry & Door Closures

Track record

SIGNAGE

Opportunity

TV Screens & Graphic Elements

SMALL

LARGE

Flooring

Benefits

Walls

Ceilings

LIGHTING

Visual Merchandising

Garbage Room Design Requirements

External Terrace

Signage Maintenance

Definitions

OFFICE MANAGMENT MALL

GENERAL MALL MANAGMENT

TECNICHAL MANAGMENT

OPERATION MANAGMENT

FIT OUT MANAGMENT

MARKETING MANAGMENT

RD

Retail Designer

RDT

Retail Delivery Team

FDA

Final Design Approva

Final Design Approva

LOD

Lease Outline Drawing

F & B

Food & Beverage

BOH

Back of House

BMS

Building Management System

LOP

Late Opening Penalty

TVR

(Tenant) Variation Request

ATTACHMENT

Required Design Architectural Documentation

Initial Concept Design Submission

Preliminary Design Submission

MEP Design Submission

Final Design Submission

FORMS

Form 03 User Authorized Representative Details

Form 06 User Variation Request

Form 11 Tenancy Handover

Form 12 Actual Fit out Commencement

Form 13 Minutes of Meeting

Form 18 Fit out Completion Summary Report

Form 22A Store Fit out Snag List – Architecture

Form 22E Store Fit out Snag List – Electrical

Form 22HF Store Fit out Snag List – Fire Protection

Form 22HP Store Fit out Snag List – Plumbing

Form 22M Store Fit out Snag List – Mechanical

Form 24 Fit out Handover Form

REQUIRMENT APPROVAL

1-2-3-4-5-6-7

1- Submission Requirement

_ All drawings must be submitted at 1:50 scale

_ Enlarged details at 1:5/ 1:10 required for Final Design Submission

_ Plans for Anchor Stores and units bigger than 750 sqm. can be submitted at 1:100 scale

_ All drawings must be fully dimensioned, referenced and annotated in English.

_ Materials and finishes to be used must be clearly indicated on drawings.

_ Samples provided must portray the true physical properties of proposed materials including the manufacturers'

details and be referenced to indicate intended location of usage

2- submitted:
DESIGN SUBMISSION

Detailed floor plan

Electrical plan

Floor finishes plan

Merchandise and fixtures plan

Furniture plan and specification

Reflected ceiling plan

All internal sections

All elevations (External & Internal)

Shop front elevation & section

shop front details

Intertenancy nib wall detail

internal joinery details

External & Internal 3D Rendering

Final finishes board & specification

(Approved finishes to be submitted)

3- submitted GRAPHICS

shop front signage details

Graphic/ VM package

5- submitted STRUCTURAL

Structural Engineers glazing drawings\

Glazing specification schedule

Structural Engineers certificate

6- submitted LIGHTING

Lighting plan

Lighting specification schedule

Samples of light fittings (where Req)

3D light rendering (Lux & Color Temp)

7- submitted SERVICE

Core hole location plan (Incl size of core)

Plumbing and drainage plan

Location and housing detail for:

SUBMISSION CHECKLIST

1-2-3-4

Initial Concept Submissions

Preliminary Design Submissions

MEP Design Submission

Final Design Submission (FDA)

Main topic

UNIVERSAL ACCESS

Ramps

Service Counters

Automated Teller Machines (ATM’s)

Clothes Shops

Supermarkets

Shops

General

Restrooms

MICA RAD

Milestones

Next steps

Risks

DELIVERY

Service’s User Portal

c1m

Responsibilities

Equipment

Equipment

Retail Delivery Process

Process

Process

Retailer Briefing Meeting

Development projects

Initial Concept Design Submission

Staff and skills

Preliminary Design Submission

Supplier or partner

Services Submission

Detail MEP

Architectural Design

Final Design Submission

User Variation Request (TVR)

Pre-approved List of Fit out Contractors and MEP Subcontractors

Floating topic